Why you should monitor relative humidity in curing concrete

Why you should monitor relative humidity in curing concrete
Warehouse humidity measurements for paper storage and cardboard monitoring
CO2 monitoring in livestock: long overdue
Innovative monitoring of embankments along the A10 with Reporter
A weather station with water level sensor for a marina or harbour
Colruyt Group uses Reporter for soil moisture measurements at the organic farm Het Zilverleen
Salinity detection in groundwater: Monitoring salt levels during dewatering
Royal Latem Golf Club uses Reporter for water monitoring
Connecting a water flow sensor to the cloud
Sensor adapters, what are they and how do they work?
Rode Rozen & Tortilla's uses Reporter for reliable temperature monitoring
Artes Woudenberg uses Reporter for wind monitoring during restoration of Brussels Palace of Justice
Smart sensors for ports and terminals
Rain monitoring for dry bulk terminals and ports
Pluym - Van Loon uses Reporter for groundwater level monitoring at construction sites
Construction site monitoring - safety & efficiency
Effective industrial odour monitoring
Why temperature control is incomplete without remote monitoring
Taste Restaurantgroup uses Reporter for freezer monitoring
Cemminerals uses Reporter to measure the temperature of canal water
Rombaut Plant uses Reporter for frost monitoring in potted plants
Vandijk Technics uses Reporter for temperature registration in cold rooms
Combined relative air humidity and leaf wetness measurement
Innovative tree monitoring: Ecomatik dendrometer integrated with Reporter
De Bossen measures soil moisture for a bountiful pole bean harvest
TM Edison uses Reporter during the construction of energy island
What is the difference between direct vs indirect energy meters?
Weather monitoring: measuring wind at a festival site
Choose the right flow meter for your next water project
How to measure Dew Point and Wet Bulb temperature
Precision test for the Sensirion SHT35 humidity sensor
Installing a weather station on caravans, holiday homes or recreational vehicles
The effect of wind on measuring particulate matter
Connecting a Watermark sensor to the cloud
Watermark vs SMT100: volumetric water content or soil water tension?
Smart geotechnical data gathering and interpretation
6 tips for making the most of your cold room
Temperature registration for HACCP
Quickly tackle the 7 principles of HACCP
6 lists to quickly get started with HACCP
Monitoring soil moisture contents for crop farming
Green Wall Monitoring: Why your vertical garden needs smart garden sensors
How is Reporter powered?
Storm & scaffolding: leveraging weather stations for enhanced construction site safety
Level measurement in a container or well
The ease of Reporter: Sumaq's a fan!
Protecting fruit tree blossoms from freezing
Adverse weather warning for your construction site
Real-time Frost Monitoring & Alert System
Pseudomonas syringae prevention in fruit trees
Cold storage of cut flowers with temperature monitoring

There's no better feeling than finishing up a project. So you just finished pouring fresh concrete, but now it's important to start monitoring the curing process. As a professional, you're probably aware that concrete needs just the right amount of moisture. Not enough water can make your concrete brittle and dry. Too much water on the other hand can make your concrete weak and porous.

To encourage just the right curing conditions, it might be necessary to add water to the surface of your curing concrete or add a dehumidifier.

Why monitoring freshly poured concrete is important

Concrete is formed when certain compounds in the cement mix hydrate, using water molecules. If the water evaporates faster than the cement compounds can hydrate, the mixture becomes dry and brittle. This can cause cracking, shrinkage, and other defects in concrete. The top layer of curing concrete can easily get damaged this way, when it dries out too fast.

At the same time, a concrete mixture that is too wet can cause the concrete to become weak. During the formation of concrete, Calcium Silicate Hydrates are formed, this is a thick gel. When this gel becomes too diluted, it loses its strength.

concrete curing

Why does concrete become too wet or too dry?

Environmental factors such as temperature, relative humidity, and dew point pose a significant impact on concrete curing. As the relative humidity is high it may affect the evaporation rates within the concrete mixture. If the mixture stays too wet for too long, the above-mentioned problems may arise.

Similarly, extremely low relative humidity may cause the concrete mixture to dry out too fast. If this happens, the Calcium Silicate Hydrates do not have enough time to form. This causes the mixture to not be able to reach its full potential, making it to be brittle and dry.

Please note that concrete drying and concrete curing are not the same. Curing is the process in which concrete hardens as the Calcium Silicate Hydrates crystallize within the material.

Influence of the weather

Other environmental factors such as sun intensity, wind, storm or rain can also affect concrete curing. Naturally, rain will add more moisture to the surface of the freshly poured concrete. While a sunny day with a strong breeze can rapidly evaporate moisture from within the mixture, before the Calcium Silicate Hydrates had time to form.

concrete curing

A final environmental factor to keep in mind when pouring concrete is of course temperature. Warm temperatures will cause your concrete mixture to dry out faster, as the water molecules from within the mixture evaporate. Due to hot weather and intense sun, excessive evaporation can take place. The water inside of the concrete mixture will evaporate faster than the compounds in the cement can hydrate and crystallise. In particular, the surface of the fresh concrete is in danger of ‘drying out’, rather than curing.

Colder temperatures can strongly hinder water molecules from escaping the mixture. This is due to dew point temperature. Dew point temperature is the temperature at which water condensates. The higher the relative humidity, the higher the dew point temperature. The colder the air, the less water vapour it can hold. Therefore pouring concrete in autumn or winter means that the surrounding air has a harder time absorbing the water molecules that are released from the mixture. Meaning that a layer of condensation or water is very likely to form on top of the curing concrete.

The advantages of monitoring curing concrete

To ensure that your construction firm can deliver the highest quality concrete, it would be advisable to implement remote monitoring during the curing of your concrete. This way you can be sure that the concrete meets the required strength and durability standards. Remote monitoring will also help you optimise your construction planning as you are completely sure whether your concrete is dry enough to move on to the next step in your planning.

Relative humidity sensors for concrete curing

A relative humidity sensor can help measure the status of your concrete in real-time. Ideally, this sensor would have some sort of feature that could warn you whenever the conditions during the curing process become sub-optimal. After all, concrete that is weak or brittle does not have the properties it is supposed to have.

curing concrete cracked

A freshly poured concrete floor that is still wet will cause the flooring that is installed on top to be damaged. Excess moisture that is trapped inside the concrete will try to evaporate. This vapour built-up becomes pressurised and can break off the top of the concrete slab. When inspection finds out that your concrete is sub-par, you will most likely have to redo your work. Which causes enormous delays and makes you to have to redo your planning.

These delays can also lead to extra costs. The longer a project goes on, the more it will cost. Staff will have to be paid and machinery might have to be rented. To prevent extra costs from arising, it is beneficial to make the project move along as quickly as possible.

The remote RH sensor can help optimise the use of resources, as you will have to use fewer additives. It helps you reduce costs as you don't need someone to manually measure the relative humidity in your concrete. Besides, it could very well avoid the need for repairs and replacements in the future.

To summarise: monitoring your concrete can reduce costs, prevent delays, prevent damage, and reduce manual labour.

Reporter to monitor concrete curing

The ideal professional solution: Reporter

Monitoring curing concrete needn't be overly complicated. Modern solutions that will assist you and your crew are readily available. One such solution is Reporter, our sensor module for remote monitoring.

Reporter's key features are sure to make you fall in love with it. Reporter was designed to make life easier, meaning that setting up your measuring projects becomes a breeze.

Connectivity

Don't worry about internet & connectivity, Reporter uses cellular data to transfer its measurements to the cloud. There is no need to acquire a Wi-Fi connection.

Especially when your construction site is in the middle of nowhere, where no power grid is available. Or where power is unreliable, this can be a huge advantage.

On the Crodeon Dashboard, which is our cloud platform, you can view your life measurements or export and analyse historical data.

Power

Speaking of power, Reporter is compatible with both solar power as well as grid power. When you choose the solar-powered option, Reporter comes with its own small but powerful solar panel. The grid-powered option uses an adapter plug.

solar powered monitoring device

Alarm notifications

In the Crodeon Dashboard, you can adjust any settings you want. Such as measuring interval or alarm thresholds. Alarm notifications will keep you up-to-date, 24/7, about your fresh concrete.

Reporter's real-time alarm notification feature, can help your construction firm quickly identify any issues during the curing process. This prevents future problems or significant delays in your planning

Combined measuring

Reporter has up to four connectors, to which you can connect up to four sensors. This means that in addition to a relative humidity sensor, you can also attach a weather station for your construction site, a submersible level sensor, and an ultrasonic flow meter.

This way you can combine all of your measuring needs into one single device: Reporter, the ideal professional solution.

Remote monitoring sensors

A concrete plan

Materials are expensive and your time and effort are costly. It would be a waste to have to redo all the work of pouring new concrete and having to wait for it to cure all over again. A simple remote monitoring device like Reporter, which keeps you posted about the conditions at your construction site, will save you a lot of time and money.

Stop sending someone over for manual measurements, when Reporter can do all of this for you. Leave your construction sites with peace of mind, as you can trust in Reporter to be your extra pair of eyes.

€499

Are you ready to make your construction site smarter with remote monitoring for concrete curing? Don't waste any more time and contact us today.

 

You might also be interested in:

 

Read more about the effects of humidity on curing concrete:

Influence of initial curing humidity on compressive strength and ultrasonic properties of concrete. 2014

Das, Bibhuti & Singh, Devendra & Pandey, S.P.

Indian Concrete Journal. 88. 48-55.

Back to blog

Any questions?

Call us at +32474097705 Or use the contact form

1 of 4
  • Demo laptop

    Live online demo

    Sign up for a free account on the Crodeon Dashboard a watch a real live working demo.

    Watch the demo 
  • person

    Talk to sales

    Schedule an appointment with Jonathan, our Sales Manager, for more information about this solution.

    Schedule a call 
  • phone email

    Contact us

    For partnerships, distribution, or any other question, don't hesistate to contact us!

    Contact us